{"product_id":"eaton-xtce009b01t-contactor-24vac-coil-3-pole","title":"Eaton XTCE009B01T Contactor 24VAC Coil 3-Pole","description":"\u003ch2 data-section-id=\"rmw5tv\" data-start=\"1416\" data-end=\"1430\"\u003eDescription\u003c\/h2\u003e\n\u003cp data-start=\"1432\" data-end=\"1823\"\u003eThe \u003cstrong data-start=\"1436\" data-end=\"1467\"\u003eEaton XTCE009B01T Contactor\u003c\/strong\u003e is a compact IEC-rated motor control contactor designed for industrial switching and motor control applications. Featuring a \u003cstrong data-start=\"1593\" data-end=\"1615\"\u003e24VAC 50\/60Hz coil\u003c\/strong\u003e, \u003cstrong data-start=\"1617\" data-end=\"1634\"\u003e3 power poles\u003c\/strong\u003e, and \u003cstrong data-start=\"1640\" data-end=\"1679\"\u003e1 normally closed auxiliary contact\u003c\/strong\u003e, this contactor provides reliable performance for automation panels, motor starters, machinery, HVAC systems, and industrial control equipment.\u003c\/p\u003e\n\u003cp data-start=\"1825\" data-end=\"2111\"\u003eThe XTCE009B01T supports motor loads up to \u003cstrong data-start=\"1868\" data-end=\"1895\"\u003e5.5 kW at 415\/440V AC-3\u003c\/strong\u003e and complies with \u003cstrong data-start=\"1914\" data-end=\"1930\"\u003eIEC\/EN 60947\u003c\/strong\u003e standards for industrial switching devices. Its compact design and durable construction make it suitable for OEM equipment, manufacturing plants, utilities, and process industries.\u003c\/p\u003e\n\u003cp data-start=\"2113\" data-end=\"2321\"\u003eWeSellStocks.co supplies Eaton motor control and automation components to EPC contractors, industrial procurement teams, maintenance departments, OEMs, and distributors across the \u003cstrong data-start=\"2293\" data-end=\"2320\"\u003eUSA, UAE, and Worldwide\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"2323\" data-end=\"2326\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"2328\" data-end=\"2355\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2357\" data-end=\"2821\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2357\" data-end=\"2384\"\u003e\n\u003ctr data-start=\"2357\" data-end=\"2384\"\u003e\n\u003cth data-start=\"2357\" data-end=\"2373\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2373\" data-end=\"2384\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2412\" data-end=\"2821\"\u003e\n\u003ctr data-start=\"2412\" data-end=\"2429\"\u003e\n\u003ctd data-start=\"2412\" data-end=\"2420\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2420\" data-end=\"2429\" data-col-size=\"sm\"\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2430\" data-end=\"2459\"\u003e\n\u003ctd data-start=\"2430\" data-end=\"2444\" data-col-size=\"sm\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-start=\"2444\" data-end=\"2459\" data-col-size=\"sm\"\u003eXTCE009B01T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2460\" data-end=\"2501\"\u003e\n\u003ctd data-start=\"2460\" data-end=\"2475\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2475\" data-end=\"2501\" data-col-size=\"sm\"\u003eIEC Magnetic Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2502\" data-end=\"2530\"\u003e\n\u003ctd data-start=\"2502\" data-end=\"2520\" data-col-size=\"sm\"\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2520\" data-end=\"2530\"\u003e3 Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2531\" data-end=\"2555\"\u003e\n\u003ctd data-start=\"2531\" data-end=\"2546\" data-col-size=\"sm\"\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd data-start=\"2546\" data-end=\"2555\" data-col-size=\"sm\"\u003e24VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2556\" data-end=\"2585\"\u003e\n\u003ctd data-start=\"2556\" data-end=\"2573\" data-col-size=\"sm\"\u003eCoil Frequency\u003c\/td\u003e\n\u003ctd data-start=\"2573\" data-end=\"2585\" data-col-size=\"sm\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2586\" data-end=\"2615\"\u003e\n\u003ctd data-start=\"2586\" data-end=\"2607\" data-col-size=\"sm\"\u003eAuxiliary Contacts\u003c\/td\u003e\n\u003ctd data-start=\"2607\" data-end=\"2615\" data-col-size=\"sm\"\u003e1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2616\" data-end=\"2644\"\u003e\n\u003ctd data-start=\"2616\" data-end=\"2638\" data-col-size=\"sm\"\u003eAC-3 Current Rating\u003c\/td\u003e\n\u003ctd data-start=\"2638\" data-end=\"2644\" data-col-size=\"sm\"\u003e9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2645\" data-end=\"2688\"\u003e\n\u003ctd data-start=\"2645\" data-end=\"2677\" data-col-size=\"sm\"\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd data-start=\"2677\" data-end=\"2688\" data-col-size=\"sm\"\u003e690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2689\" data-end=\"2726\"\u003e\n\u003ctd data-start=\"2689\" data-end=\"2719\" data-col-size=\"sm\"\u003eRated Thermal Current (Ith)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2719\" data-end=\"2726\"\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2727\" data-end=\"2761\"\u003e\n\u003ctd data-start=\"2727\" data-end=\"2752\" data-col-size=\"sm\"\u003eImpulse Voltage (Uimp)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2752\" data-end=\"2761\"\u003e8000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2762\" data-end=\"2789\"\u003e\n\u003ctd data-start=\"2762\" data-end=\"2773\" data-col-size=\"sm\"\u003eStandard\u003c\/td\u003e\n\u003ctd data-start=\"2773\" data-end=\"2789\" data-col-size=\"sm\"\u003eIEC\/EN 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2790\" data-end=\"2821\"\u003e\n\u003ctd data-start=\"2790\" data-end=\"2810\" data-col-size=\"sm\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd data-start=\"2810\" data-end=\"2821\" data-col-size=\"sm\"\u003eRomania\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2823\" data-end=\"2826\"\u003e\n\u003ch2 data-section-id=\"mu966k\" data-start=\"2828\" data-end=\"2843\"\u003eApplications\u003c\/h2\u003e\n\u003cul data-start=\"2845\" data-end=\"3032\"\u003e\n\u003cli data-section-id=\"h9tfao\" data-start=\"2845\" data-end=\"2874\"\u003eMotor Control Centers (MCC)\u003c\/li\u003e\n\u003cli data-section-id=\"ym6xrp\" data-start=\"2875\" data-end=\"2905\"\u003eIndustrial Automation Panels\u003c\/li\u003e\n\u003cli data-section-id=\"mc73fm\" data-start=\"2906\" data-end=\"2920\"\u003eHVAC Systems\u003c\/li\u003e\n\u003cli data-section-id=\"uifzge\" data-start=\"2921\" data-end=\"2948\"\u003ePump Control Applications\u003c\/li\u003e\n\u003cli data-section-id=\"lnxerv\" data-start=\"2949\" data-end=\"2967\"\u003eConveyor Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1uye18h\" data-start=\"2968\" data-end=\"2983\"\u003eOEM Machinery\u003c\/li\u003e\n\u003cli data-section-id=\"1982k8s\" data-start=\"2984\" data-end=\"3006\"\u003eManufacturing Plants\u003c\/li\u003e\n\u003cli data-section-id=\"7hfq0i\" data-start=\"3007\" data-end=\"3032\"\u003eProcess Control Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3061\" data-end=\"3242\"\u003eSource Eaton XTCE009B01T contactors and industrial motor control components for automation upgrades, OEM machinery, electrical panels, and industrial maintenance projects worldwide.\u003c\/p\u003e\n\u003chr data-start=\"3244\" data-end=\"3247\"\u003e\n\u003ch2 data-section-id=\"1ls49mx\" data-start=\"3249\" data-end=\"3262\"\u003eMetafields\u003c\/h2\u003e\n\u003cp data-start=\"3264\" data-end=\"3786\"\u003e\u003cstrong data-start=\"3264\" data-end=\"3274\"\u003ebrand:\u003c\/strong\u003e Eaton\u003cbr data-start=\"3280\" data-end=\"3283\"\u003e\u003cstrong data-start=\"3283\" data-end=\"3299\"\u003epart_number:\u003c\/strong\u003e XTCE009B01T\u003cbr data-start=\"3311\" data-end=\"3314\"\u003e\u003cstrong data-start=\"3314\" data-end=\"3331\"\u003eproduct_type:\u003c\/strong\u003e IEC Magnetic Contactor\u003cbr data-start=\"3354\" data-end=\"3357\"\u003e\u003cstrong data-start=\"3357\" data-end=\"3368\"\u003eseries:\u003c\/strong\u003e XTCE\u003cbr data-start=\"3373\" data-end=\"3376\"\u003e\u003cstrong data-start=\"3376\" data-end=\"3396\"\u003enumber_of_poles:\u003c\/strong\u003e 3 Pole\u003cbr data-start=\"3403\" data-end=\"3406\"\u003e\u003cstrong data-start=\"3406\" data-end=\"3423\"\u003ecoil_voltage:\u003c\/strong\u003e 24VAC\u003cbr data-start=\"3429\" data-end=\"3432\"\u003e\u003cstrong data-start=\"3432\" data-end=\"3451\"\u003ecoil_frequency:\u003c\/strong\u003e 50\/60 Hz\u003cbr data-start=\"3460\" data-end=\"3463\"\u003e\u003cstrong data-start=\"3463\" data-end=\"3486\"\u003eauxiliary_contacts:\u003c\/strong\u003e 1 NC\u003cbr data-start=\"3491\" data-end=\"3494\"\u003e\u003cstrong data-start=\"3494\" data-end=\"3517\"\u003eac3_current_rating:\u003c\/strong\u003e 9A\u003cbr data-start=\"3520\" data-end=\"3523\"\u003e\u003cstrong data-start=\"3523\" data-end=\"3552\"\u003erated_insulation_voltage:\u003c\/strong\u003e 690V AC\u003cbr data-start=\"3560\" data-end=\"3563\"\u003e\u003cstrong data-start=\"3563\" data-end=\"3589\"\u003erated_thermal_current:\u003c\/strong\u003e 20A\u003cbr data-start=\"3593\" data-end=\"3596\"\u003e\u003cstrong data-start=\"3596\" data-end=\"3616\"\u003eimpulse_voltage:\u003c\/strong\u003e 8000V\u003cbr data-start=\"3622\" data-end=\"3625\"\u003e\u003cstrong data-start=\"3625\" data-end=\"3638\"\u003estandard:\u003c\/strong\u003e IEC\/EN 60947\u003cbr data-start=\"3651\" data-end=\"3654\"\u003e\u003cstrong data-start=\"3654\" data-end=\"3676\"\u003ecountry_of_origin:\u003c\/strong\u003e Romania\u003cbr data-start=\"3684\" data-end=\"3687\"\u003e\u003cstrong data-start=\"3687\" data-end=\"3701\"\u003econdition:\u003c\/strong\u003e Surplus \/ Used\u003cbr data-start=\"3716\" data-end=\"3719\"\u003e\u003cstrong data-start=\"3719\" data-end=\"3736\"\u003estock_status:\u003c\/strong\u003e Available Upon Request\u003cbr data-start=\"3759\" data-end=\"3762\"\u003e\u003cstrong data-start=\"3762\" data-end=\"3782\"\u003eglobal_shipping:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003ch5 data-start=\"3264\" data-end=\"3786\"\u003eCondition: New Open Box\u003c\/h5\u003e","brand":"We Sell Stocks","offers":[{"title":"Default Title","offer_id":51917473644830,"sku":"Cabin : EU-30","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0807\/7230\/1086\/files\/7_3e85148e-5916-473a-9e5a-1c5115e14126.png?v=1780395456","url":"https:\/\/wesellstocks.co\/products\/eaton-xtce009b01t-contactor-24vac-coil-3-pole","provider":"We Sell Stocks","version":"1.0","type":"link"}