{"product_id":"abb-ta80du-52-thermal-overload-relay-1saz331201r1004-36-52a","title":"ABB TA80DU-52 Thermal Overload Relay 1SAZ331201R1004 36–52A","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe ABB TA80DU-52 thermal overload relay is a globally specified motor protection device engineered for reliable overload detection across a broad range of industrial motor control applications. Rated for a current adjustment range of 36–52A with Trip Class 10A, this relay operates at insulation voltage up to 690V and impulse withstand voltage of 6kV, conforming to EN\/IEC 60947-4-1\/-5-1 and GB 14048.4\/.5 international standards. UL listed and CCC certified, the TA80DU-52 is fully compliant for both USA and international industrial installations. Auxiliary contact ratings include NO C600 and NC B600 for same polarity above 300V, with AC-15 and DC-13 switching capabilities confirmed. Industrial procurement teams across the USA source ABB TA80DU series overload relays for motor starter assemblies, MCC panels, and MRO replacement programs. Electrical contractors and switchgear builders in the UAE rely on ABB thermal overload relays for motor protection in pumping, HVAC, and process automation installations. WeSellStocks.co supplies verified ABB motor control and protection equipment to qualified buyers Worldwide at competitive wholesale terms.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Thermal Overload Relay\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e TA80DU-52\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eOrder Code:\u003c\/strong\u003e 1SAZ331201R1004\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eCurrent Setting Range:\u003c\/strong\u003e 36–52A\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eTrip Class:\u003c\/strong\u003e 10A\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eInsulation Voltage (Ui):\u003c\/strong\u003e 690V\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eOperational Voltage (Ue):\u003c\/strong\u003e 690V\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp):\u003c\/strong\u003e 6 kV\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eMax Operating Voltage (AC):\u003c\/strong\u003e 600 Vac\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eAuxiliary Contacts:\u003c\/strong\u003e NO C600 \/ NC B600 (same polarity above 300V)\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eAC-15 Ratings:\u003c\/strong\u003e 240V — NC: 3.0A \/ NO: 1.5A | 440V — NC: 1.0A \/ NO: 1.0A | 500V — NC: 1.0A \/ NO: 1.0A\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eDC-13 Ratings:\u003c\/strong\u003e 24V — 1.25A \/ 1.25A | 125V — 0.25A \/ 0.25A | 250V — 0.12A \/ 0.04A\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eFuses gG NC \/ NO:\u003c\/strong\u003e 10A \/ 6A\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eMain Wiring:\u003c\/strong\u003e 8–1 AWG \/ 40 lb-in (75°C Cu stranded wire only)\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eAuxiliary Wiring:\u003c\/strong\u003e 18–14 AWG \/ 12 lb-in\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eStandards \/ Compliance:\u003c\/strong\u003e EN\/IEC 60947-4-1\/-5-1 | GB 14048.4\/.5 | UL Listed (94D7) | CCC | CE\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Czech Republic\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eDate Code:\u003c\/strong\u003e 1303\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Available upon request\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe ABB TA80DU-52 is designed for direct mounting onto ABB A-series contactors in motor control centers, starter panels, and standalone motor protection applications. It provides bimetallic thermal overload protection for three-phase and single-phase motors in pumps, fans, compressors, conveyors, and process machinery operating in industrial and commercial environments. Its wide current setting range of 36–52A accommodates multiple motor ratings within a single relay frame, reducing inventory SKU requirements for MRO and panel-building procurement teams. The relay's multi-standard certification makes it suitable for deployment in international projects across IEC, UL, and GB regulated markets.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eABB TA80DU-52 and the broader TA80DU series remain among the most consistently sourced thermal overload relays in global motor control procurement, specified by panel builders, EPC contractors, and MRO buyers across industrial sectors. WeSellStocks.co operates as a wholesale and surplus distributor for ABB motor protection and control equipment, servicing procurement teams across the USA, UAE, and internationally. Organizations requiring verified ABB overload relay stock, motor starter components, or volume MCC panel equipment are encouraged to submit direct commercial inquiries.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eMetafields:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003ebrand:\u003c\/strong\u003e ABB\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003epart_number:\u003c\/strong\u003e TA80DU-52\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eorder_code:\u003c\/strong\u003e 1SAZ331201R1004\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eproduct_type:\u003c\/strong\u003e Thermal Overload Relay\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eindustry_category:\u003c\/strong\u003e Industrial Automation \/ Motor Control \u0026amp; Protection\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003ecurrent_setting_range:\u003c\/strong\u003e 36–52A\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003etrip_class:\u003c\/strong\u003e Class 10A\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003einsulation_voltage:\u003c\/strong\u003e 690V\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eoperational_voltage:\u003c\/strong\u003e 690V\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eimpulse_withstand_voltage:\u003c\/strong\u003e 6 kV\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003emax_ac_voltage:\u003c\/strong\u003e 600 Vac\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eip_rating:\u003c\/strong\u003e IP20\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eauxiliary_contacts:\u003c\/strong\u003e NO C600 \/ NC B600\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003emain_wiring:\u003c\/strong\u003e 8–1 AWG \/ 40 lb-in\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eauxiliary_wiring:\u003c\/strong\u003e 18–14 AWG \/ 12 lb-in\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003estandards:\u003c\/strong\u003e EN\/IEC 60947-4-1\/-5-1 | GB 14048.4\/.5 | UL Listed 94D7 | CCC | CE\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003ecountry_of_origin:\u003c\/strong\u003e Czech Republic\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003edate_code:\u003c\/strong\u003e 1303\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003econdition:\u003c\/strong\u003e Available upon request\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003estock_quantity_available:\u003c\/strong\u003e Available upon request\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003etarget_markets:\u003c\/strong\u003e USA | UAE | Worldwide\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eglobal_shipping:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003ch5 class=\"font-claude-response-body break-words whitespace-normal\"\u003eCondition: New Open Box\u003c\/h5\u003e","brand":"We Sell Stocks","offers":[{"title":"Default Title","offer_id":59483176337694,"sku":"Cabin : 86-1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0807\/7230\/1086\/files\/4_a23d55c6-2e18-44a1-b8fc-97f1acf22f4a.png?v=1781789450","url":"https:\/\/wesellstocks.co\/products\/abb-ta80du-52-thermal-overload-relay-1saz331201r1004-36-52a","provider":"We Sell Stocks","version":"1.0","type":"link"}